Bolt Bonnet OS&Y Satinless Steel CF8c Flanged Gate Valve

  • Model NO.: Z41H
  • Material: Carbon Steel
  • Pressure: Ordinary Pressure
  • Seal Surface: Wedge Gate Valve
  • Usage: Flow Control
  • Application: Industrial Usage, Water Industrial Usage
  • Class: 150lb to 2500lb
  • Application Fields: Metallurgy,Light Industrial,Electric Power,Petroch
  • Trademark: NAIBANG
  • Specification: API, ANSI, DIN, Bs, JIS
  • HS Code: 8481804090
  • Type: Straight-through
  • Connection Form: Flange
  • Actuator: Manual
  • Thread Position of Valve Rod: Outside Gate Valve
  • Standard: ANSI
  • Size: 1/2" to 2"
  • Certificates: API 6D, Ce, ISO9001
  • Delivery Detail: 20~45 Days According to The Specific Quantities
  • Transport Package: Standard Export Wooden Case
  • Origin: China
Bolted Bonnet Gate Valve

Main Parameter Specification
Design and Manufacture:Cast Steel Gate Valve to API 600(ISO 10434),API 6D;Cast Stainless Steel Gate Valve to API 603,API 600
Inspection and Test:API598,API600 or API 6D
End Flange Dimension:ASME B16.5(for NPS≤24,ASME B 16.47 series B,API 605,ASME B16.47 A Series,MSS SP-44(for NPS>24)
BW end Dimension:ASME B16.25
Face to Face and End to End:ASME B16.10
Pressure-temperature ratings:ASME B16.34
Product Range
Body material: carbon steel, stainless steel, alloy steel
Nominal diameter:2"~36"(DN50~DN900)
End Connection: RF,RTJ, BW
Pressure range: Class150~900(PN16~PN150)
Working temperature:-29ºC~+560ºC
Operation: Hand wheel,Gear,Electric Actuator,etc.
 

Pressure Seal Gate Valve
Main Features:
The pressure seal valves are designed for service of high temperature and high pressure and are widely used in fossil fuel power plant. Compared with bolted bonnet joint valves,
it provides absolute reliable sealing of the bonnet joint, so that the pressure seal valves are more compact and rigid as well as maintenance cost-effective at high temperature and high pressure service.
This kind of gate valve is not only characterized as simple structure and reliable usage, but also able to create slight flexible deformation to compensate the deviation of the sealing face angle generated during processing, thus improving the process performance. In addition, at seat and gate disc seal surface are over-lay with iron-base alloy or Co-base alloy or carbide alloy for long duration.
Main Parameter Specification
Design and Manufacture:Cast Steel Gate Valve to API 600(ISO 10434),API 6D;Cast Stainless Steel Gate Valve to API 603,API 600
Inspection and Test:API598,API600 or API 6D
End Flange Dimension:ASME B16.5(for NPS≤24,ASME B 16.47 series B,API 605,ASME B16.47 A Series,MSS SP-44(for NPS>24)
BW end Dimension:ASME B16.25
Face to Face and End to End:ASME B16.10
Pressure-temperature ratings:ASME B16.34
Product Range
Body material: carbon steel, stainless steel, alloy steel
Nominal diameter:2"~36"(DN50~DN900)
End Connection: RF,RTJ, BW
Pressure range: Class150~2500(PN16~PN420)
Working temperature:-29ºC~+560ºC
Operation: Hand wheel,Gear,Electric Actuator,etc.


PRODUCTS
Bolt Bonnet OS&Y Satinless Steel CF8c Flanged Gate Valve WORKSHOP
Bolt Bonnet OS&Y Satinless Steel CF8c Flanged Gate Valve
INSECTION
Bolt Bonnet OS&Y Satinless Steel CF8c Flanged Gate Valve


We welcome all the world customers to contact us for more cooperation.

With our years of technical knowledge and experience, we assure you,

Naibang will be one of your best parters in China.
 
Specifications
Applicable Standards  
Design ASME B16.34, API6D 
Fire safe API 607 
Anti static API 608, API6D 
Face to face ASME B16.10, API6D
Welding ends ASME B16.25
Inspection and test API 598, API 6D  

Combined Flow Closed Cooling Tower

Closed Cooling Tower is operated by circulating water or fluid, which is divided into two closed loops.

1. Circulation in the tower: the circulating water or fluid passes through the hot zone environment. After the water temperature rises, it enters the surface cooler in the tower, and the heat is sent to the environment outside the tower through the surface cooler and ventilation fan. The cooled circulating water or fluid is sent to the heat source by the water pump.


2. Circulation outside the tower: the spray water is sent to the spray system by the water tank through the water pipe. After spraying, the spray water first exchanges heat with the filler, so that the spray water can be cooled rapidly. At this time, the water contacts the surface of the surface cooler for heat exchange. Part of the hot steam is discharged through the ventilation fan, and the cooled spray water drops to the water tank for secondary circulation to form an external circulation for cooling.

Combined Flow Closed Cooling Tower,Bac Cooling Tower,Cooling Tower Systems,Chiller Tower

Wuxi Ark Fluid Science Technology Co., Ltd. , https://www.fangzhou-arkfluid.com